150KW-1100KW SHKP Series Diesel Generator Set
Min.Order : 1 Pieces Quick Quotation >
Conpany Profile
Product Details
Equipped with one professional factory, TONGJI manufactures quality 150kw-1100kw shkp series diesel generator set in China, welcome to buy cheap and discount 150kw-1100kw shkp series diesel generator set from our factory or check the quotation with us.
| 150KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-150 | Rated voltage:400V/230V |
| Power(KW):150Kw | Rated frequency:50Hz |
| Current(A):270A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:6135AZD-1 | Diesel motor power(KW):171Kw |
| Number of Cylinder:6 | Compression ratio:17:1 |
| Bore*stroke:135×150mm | Air intake mode:turbocharging |
| Displacement(L):12.7 | Capacity of overload:110% |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:TZH2-150 | Connection mode:three-phase four wire,Y type connection |
| Power:150kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:1500 | |
| Implementation of industry standards GB/T19001-1508 | |
| 200KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-200 | Rated voltage:400V/230V |
| Power(KW):200Kw | Rated frequency:50Hz |
| Current(A):360A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KP206 | Diesel motor power(KW):206Kw |
| Number of Cylinder:6 | Compression ratio:17:1 |
| Bore*stroke:135×150mm | Air intake mode:turbocharging |
| Displacement(L):12.7 | Capacity of overload:110% |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:TZH2-200 | Connection mode:three-phase four wire,Y type connection |
| Power:200kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H? | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:2000 | |
| Implementation of industry standards GB/T19001-2008 | |
| 200KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-200 | Rated voltage:400V/230V |
| Power(KW):200Kw | Rated frequency:50Hz |
| Current(A):360A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KP227 | Diesel motor power(KW):227Kw |
| Number of Cylinder:6 | Compression ratio:17:1 |
| Bore*stroke:135×150mm | Air intake mode:turbocharging |
| Displacement(L):12.7 | Capacity of overload:110% |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:TZH2-200 | Connection mode:three-phase four wire,Y type connection |
| Power:200kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:2000 | |
| Implementation of industry standards GB/T19001-2008 | |
| 250KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-250 | Rated voltage:400V/230V |
| Power(KW):250Kw | Rated frequency:50Hz |
| Current(A):450A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2950×1030×1600(L×W×H mm) | Weight:2300kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KP250 | Diesel motor power(KW):263Kw |
| Number of Cylinder:6 | Compression ratio:17:1 |
| Bore*stroke:135×150mm | Air intake mode:turbocharging |
| Displacement(L):14.2 | Capacity of overload:110% |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:TZH2-250 | Connection mode:three-phase four wire,Y type connection |
| Power:250kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H? | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:2000 | |
| Implementation of industry standards GB/T19001-2008 | |
| 300KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-300 | Rated voltage:400V/230V |
| Power(KW):300Kw | Rated frequency:50Hz |
| Current(A):540A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:3000×1100×1700(L×W×H mm) | Weight:2500kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KP310 | Diesel motor power(KW):316Kw |
| Number of Cylinder:6 | Compression ratio:17:1 |
| Bore*stroke:135×155mm | Air intake mode:turbocharging |
| Displacement(L):13.3 | Capacity of overload:110% |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:TZH2-300 | Connection mode:three-phase four wire,Y type connection |
| Power:300kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H? | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:2000 | |
| Implementation of industry standards GB/T19001-2008 | |
| 350KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-350 | Rated voltage:400V/230V |
| Power(KW):350Kw | Rated frequency:50Hz |
| Current(A):630A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KP350 | Fuel supply way: Direct injection |
| Number of Cylinder:6 | Compression ratio:17:1 |
| Bore*stroke:135×160mm | Air intake mode:turbocharging |
| Displacement(L):12.7 | Capacity of overload:110% |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:MP-4-350 | Connection mode:three-phase four wire,Y type connection |
| Power:350kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H? | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:3500 | |
| Implementation of industry standards GB/T19001-3508 | |
| 400KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-400 | Rated voltage:400V/230V |
| Power(KW):425Kw | Rated frequency:50Hz |
| Current(A):720A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KP425 | Fuel supply way: Direct injection |
| Number of Cylinder:6 | Compression ratio:17:1 |
| Bore*stroke:135×168mm | Air intake mode:turbocharging |
| Displacement(L):14.9 | Capacity of overload:110% |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:MP-4-400 | Connection mode:three-phase four wire,Y type connection |
| Power:400kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated volage:400/230 | Frequency:50Hz |
| Insulation:H? | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:3500 | |
| Implementation of industry standards GB/T19001-3508 | |
| 400KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-400 | Rated voltage:400V/230V |
| Power(KW):420Kw | Rated frequency:50Hz |
| Current(A):720A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KPV420 | Fuel supply way: Direct injection |
| Number of Cylinder:12 | Compression ratio:17:1 |
| Bore*stroke:135×150mm | Air intake mode:turbocharging |
| Displacement(L):14.9 | Capacity of overload:110% |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:TZH2-400 | Connection mode:three-phase four wire,Y type connection |
| Power:400kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H? | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:3500 | |
| Implementation of industry standards GB/T19001-3508 | |
| 450KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-450 | Rated voltage:400V/230V |
| Power(KW):450Kw | Rated frequency:50Hz |
| Current(A):810A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KPV450 | Diesel motor power(KW):450Kw |
| Number of Cylinder:12 | Compression ratio:17:1 |
| Bore*stroke:135×150mm | Air intake mode:turbocharging |
| Displacement(L):25.8 | Capacity of overload:110% |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:MP-4-450 | Connection mode:three-phase four wire,Y type connection |
| Power:450kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:3500 | |
| Implementation of industry standards GB/T19001-3508 | |
| 500KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-500 | Rated voltage:400V/230V |
| Power(KW):510Kw | Rated frequency:50Hz |
| Current(A):900 | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KPV510 | Fuel supply way: Direct injection |
| Number of Cylinder:12 | Compression ratio:17:1 |
| Bore*stroke:135×150mm | Air intake mode:turbocharging |
| Displacement(L):25.8 | Capacity of overload:110% |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:MP-4-500 | Connection mode:three-phase four wire,Y type connection |
| Power:500kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H? | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:3500 | |
| Implementation of industry standards GB/T19001-3508 | |
| 550KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-550 | Rated voltage:400V/230V |
| Power(KW):610Kw | Rated frequency:50Hz |
| Current(A):990A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KPV550 | Fuel supply way: Direct injection |
| Number of Cylinder:12 | Compression ratio:17:1 |
| Bore*stroke:135×155mm | Air intake mode:turbocharging |
| Displacement(L):25.8 | Capacity of overload:110% |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:MP-4-550 | Connection mode:three-phase four wire,Y type connection |
| Power:550kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H? | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:3500 | |
| Implementation of industry standards GB/T19001-3508 | |
| 600KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-600 | Rated voltage:400V/230V |
| Power(KW):630Kw | Rated frequency:50Hz |
| Current(A):1080A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KPV630 | Diesel motor power:630kw |
| Number of Cylinder:12 | Compression ratio:17:1 |
| Bore*stroke:135×155mm | Air intake mode:turbocharging |
| Displacement(L):28.39 | Capacity of overload:110% |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:MP-4-600 | Connection mode:three-phase four wire,Y type connection |
| Power:600kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H? | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:3500 | |
| Implementation of industry standards GB/T19001-3508 | |
| 600KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-600 | Rated voltage:400V/230V |
| Power(KW):610Kw | Rated frequency:50Hz |
| Current(A):1080A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Displacement:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KPV610 | Fuel supply way: Direct injection |
| Number of Cylinder:12 | Compression ratio:17:1 |
| Bore*stroke:135×155mm | Air intake mode:turbocharging |
| Displacement(L):14.9 | Capacity of overload:110% |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:MP-4-600 | Connection mode:three-phase four wire,Y type connection |
| Power:600kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H? | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:3500 | |
| Implementation of industry standards GB/T19001-3508 | |
| 650KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-650 | Rated voltage:400V/230V |
| Power(KW):660Kw | Rated frequency:50Hz |
| Current(A):1170 | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KPV660 | Diesel motor power:660kw |
| Number of Cylinder:12 | Compression ratio:17:1 |
| Bore*stroke:135×158mm | Air intake mode:turbocharging |
| Displacement(L):28.36 | Capacity of overload:110% |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:MP-4-650 | Connection mode:three-phase four wire,Y type connection |
| Power:650kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400V/230V | Frequency:50Hz |
| Insulation:H? | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| 700KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-700 | Rated voltage:400V/230V |
| Power(KW):720Kw | Rated frequency:50Hz |
| Current(A):1080A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KPV720 | Diesel motor power:720kw |
| Number of Cylinder:12 | Compression ratio:17:1 |
| Bore*stroke:138×158mm | Air intake mode:turbocharging |
| Displacement(L):28.8 | Capacity of overload:110% |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:MP-4-700 | Connection mode:three-phase four wire,Y type connection |
| Power:700kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H? | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:3500 | |
| Implementation of industry standards GB/T19001-3508 | |
| 750KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-750 | Rated voltage:400V/230V |
| Power(KW):780Kw | Rated frequency:50Hz |
| Current(A):1350A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KPV780 | Diesel motor power:780kw |
| Number of Cylinder:12 | Compression ratio:17:1 |
| Bore*stroke:138×158mm | Air intake mode:turbocharging |
| Displacement(L):28.8 | Capacity of overload:110% |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:MP-4-750 | Connection mode:three-phase four wire,Y type connection |
| Power:750kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H? | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:3500 | |
| Implementation of industry standards GB/T19001-3508 | |
| 800KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-800 | Rated voltage:400V/230V |
| Power(KW):840Kw | Rated frequency:50Hz |
| Current(A):1440A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KPV840 | Diesel motor power:840kw |
| Number of Cylinder:12 | Compression ratio:17:1 |
| Bore*stroke:138×165mm | Air intake mode:turbocharging |
| Displacement(L):32.8 | Capacity of overload:110% |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:MP-4-800 | Connection mode:three-phase four wire,Y type connection |
| Power:800kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400V/230V | Frequency:50Hz |
| Insulation:H? | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:3500 | |
| Implementation of industry standards GB/T19001-3508 | |
| 900KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-900 | Rated voltage:400V/230V |
| Rated power(KW):936Kw | Rated frequency:50Hz |
| Current(A):1620A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KPV936 | Diesel motor power:936KW |
| Number of Cylinder:12 | Compression ratio:17:1 |
| Bore*stroke:138×165mm | Air intake mode:turbocharging |
| Displacement(L):28.8 | Fuel supply way:Direct injection |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:MP-4-900 | Connection mode:three-phase four wire,Y type connection |
| Power:900kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:3500 | |
| Implementation of industry standards GB/T19001-3508 | |
| 950KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-950 | Rated voltage:400V/230V |
| Power(KW):950Kw | Rated frequency:50Hz |
| Current(A):1710A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:KPV970 | Diesel motor power:970KW |
| Number of Cylinder:12 | Compression ratio:17:1 |
| Bore*stroke:138×168mm | Air intake mode:turbocharging |
| Displacement(L):32.8 | Fuel supply way:Direct injection |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:MP-4-950 | Connection mode:three-phase four wire,Y type connection |
| Power:950kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:3500 | |
| Implementation of industry standards GB/T19001-3508 | |
| 1000KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-1000 | Rated voltage:400V/230V |
| Power(KW):1000Kw | Rated frequency:50Hz |
| Current(A):1800A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:VOFM1100 | Diesel motor power:1080KW |
| Number of Cylinder:12 | Compression ratio:17:1 |
| Bore*stroke:138×165mm | Air intake mode:turbocharging |
| Displacement(L):32.7 | Fuel supply way:Direct injection |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:MP-4-1000 | Connection mode:three-phase four wire,Y type connection |
| Power:1000kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:3500 | |
| Implementation of industry standards GB/T19001-3508 | |
| 1100KW SHKP series diesel generator sets technical specification | |
| Generator set technical parameters | |
| Model number:WEB-1100 | Rated voltage:400V/230V |
| Power(KW):1100Kw | Rated frequency:50Hz |
| Current(A):1980A | Rated rotating speed:1500rpm |
| Rated power factor:COSF=0.8(Lagging) | Starting mode: electric starting |
| Dimension:2800×1030×1580(L×W×H mm) | Weight:2600kg |
| Fuel grade:(standard)0#light diesel oil(normal temperature) | Fuel consumption(100% load):231g/kW·h |
| Diesel motor technical parameters: | |
| Brand/place of origin: SHKP | Cooling way:Closed Water Cycling Cooling |
| Type:VOFM1200 | Diesel motor power:1160KW |
| Number of Cylinder:12 | Compression ratio:17:1 |
| Bore*stroke:138×168mm | Air intake mode:turbocharging |
| Displacement(L):32.7 | Fuel supply way:Direct injection |
| Starting mode: DC24V electric starting | Rotate speed:1500rpm |
| Generator technical parameters: | |
| Generator brand:Tongji generator | Protection grade:IP22 |
| Type:MP-4-1100 | Connection mode:three-phase four wire,Y type connection |
| Power:11000kW | Adjusting mode:AVR(Automatic voltage regulator) |
| Rated voltage:400/230 | Frequency:50Hz |
| Insulation:H | Output factor:COSF=0.8(Lagging) |
| Voltage fluctuation rate (%):=±0.5 | Transient voltage regulation(%):+20~-15 |
| Steady State frequency regulation :0~5% | Transient frequency regulation(%):+10~-7 |
| Voltage fluctuation rate (%):=±0.5 | Frequency fluctuation (%):=±0.5 |
| Generator set standard configuration | |
| ØDirect injection internal combustion engine (diesel); | |
| AC synchronous generator (single bearing) | |
| Suitable environment 40?-50? radiator tank, belt-driven cooling fan, protection cover of fan | |
| ØAir switch, standard configuration control panel;; | |
| Generator set steel common base (including: damping rubber blanket); | |
| ØDry-type air filter, fuel filter, lubricating oil filter, starting motor, self-charging generator; | |
| ØStarting batteries and connecting cables; | |
| ØIndustrial 9dB silencer and standard component for connection | |
| ØAttached documents: Original technique documents for diesel engine and generator, generator set instruction, test report | |
| ?Optional component (extra charge): | |
| ØEngine oil, diesel oil, water-jacket , anti-condensation heater | ØSplit-type fuel tank, integrated fuel tank base |
| Øautomatic battery charger | ØRain-proof model set(Bin) |
| ØSelf-protection, self-starting control panel | Øsilent type model set(Bin) |
| ØThree-remote function control panel | ØMobile Trailer type power station(Bin trailer) |
| ØATS | ØSilent type mobile station(Bin trailer) |
| ?executive standard: | |
| International standard certification ISO9001:3500 | |
| Implementation of industry standards GB/T19001-3508 | |
Recommend Product