DC Fuse 4 5 6 8 12A
1, DC Fuse Application specification
The fuse used to protect the PV array shall meet the following requirements:
A. The rated voltage is greater than or equal to the maximum temperature expected according to the minimum temperature at the installation site according to the manufacturer of the photovoltaic panel manufacturer or the table above;
B. DC fuse block;
C. Rated breaking capacity of not less than from the photovoltaic array, and other connected power sources such as batteries, generators and power grid fault current, if present;
D. IEC60269-6 compliant and suitable for PV overcurrent and short circuit protection.
Suntree DC fuse-fitting support for photovoltaic array protection shall comply with the following requirements:
A. The rated voltage is greater than or equal to the maximum temperature expected according to the minimum temperature at the installation site according to the manufacturer of the photovoltaic panel manufacturer or the table above;
B. Rated current greater than or equal to the rated current of the corresponding fuse;
C. The protection level is suitable for installation and not less than IP 2X.
2, DC Fuse Product Parameter
Model name | SRD-PV |
Rated current(A) | 1A,2A,3A,4A,5A,6A,8A,10A,12A,15A,20A,25A |
Rated voltage | 1000VDC /1500 V DC |
Rated breaking capacity | 20kA |
Standard specification | IEC60269-6 |
Fuse Holder | |
Pole | 1P,2P |
Rated voltage(V DC) | 1000 |
Rated current(A) | 1A,2A,3A,4A,5A,6A,8A,10A,12A,15A,20A,25A |
Rated breaking capaticy(kA) | 20kA |
The most high power consumption(W) | 3.5 |
Connection(mm2) | 2.5~10 |
Working temperature (?) | -30~+70 |
Resistance | Class 2 |
Altitude(m) | =2000 |
Relative humidity | =95% |
Protection class/degree | IP20 |
Pollution | 3 |
Installation class | Class ? |
Installation type | DIN rail |
3.DC Fuse time current property support member sketch
Time current property | |
support member sketch | |
T-l characteristic |
DC Fuse Production line
Parts of our sales team
Parts of Exhibition trade show
4, DC Fuse Use the field
Suntree DC fuse consists essentially of a melt, a housing, and a support, where the melt is a key element in controlling the fusing characteristics. The material, size and shape of the melt determine the fusing properties.
Suntree DC Fuse with anti-delay characteristics, that is, overload current is small, fuse a long time; overload current, the fuse time is short. Therefore, in a certain overload current range, when the current back to normal, the fuse will not fuse, can continue to use. Fuses have a variety of different fuse characteristics, can be applied to different types of protection needs.
5, When got issue, how to check and Overhaul:
Melt blow response measures, to really analyze the reasons for the fuse, the possible reasons are:
Short circuit fault or overload operation and normal blow.
Be sure to check the N-wire in the TN grounding system, the grounding protection line of the device, and do not allow the use of fuses
When replacing the melt, it is required to:
Melt installation mechanical damage, so that the cross-sectional area becomes smaller and in operation caused by misuse.
When replacing a new melt, check that the melt rating matches the device being protected. Maintenance Check the fuse, according to safety regulations, cut off the power, do not agree to charge the fuse tube.
Check the appearance of the fuse (remove the fuse tube) with or without damage, deformation, porcelain pieces with or without flashing marks.
Clean the dust and check the contact point.
Fuses should be repaired with the power distribution unit at the same time:
Replace the new melt, to check the internal combustion of the fuse tube, if severe burns, should also change the melting tube. Filling Filler When replacing the melt, pay attention to fill the filler.
Check the fuse, the melt and the protected circuit or equipment is matched, if the problem should be investigated in time.
Before installing the new melt, find the cause of the melt fuse, not determine the cause of the fuse, do not replace the melt test.
Melt used for too long, the melt due to oxidation or high temperature during operation, so that the characteristics of the melt and error. Porcelain melting pipe damage, do not answer the application of other material tube instead.
6, DC Fuse FAQ:
1.Payment : T/T ,paypal,western union
2.Sample lead time: 1-3days
3.Production lead time: 5 days
4.Shipping freight are delivered under your requests
5.Shipping port :Shanghai/Ningbo,mainland china
6.Discounts are offered based on order quantities
8.Packaging: 300pcs/box
9.Shipping: By Express(EMS,DHL,UPS,ARAMEX), By Air or By Sea
Recommend Product