Max. working pressure: | 10 bar |
Ambient temperature range: | -30–90°C |
Opening temperature: | 4°C |
Closing temperature: | 8°C |
Accuracy: | ±2°C |
Connections: | G3/4" or NPT3/4" |
Body material: | Brass |
Thread: | Male thread |
Net weight | 0.14 KGS |
Gross weight | 0.15 KGS |
Operating principle
A thermostatic sensor sensing the water temprature to control the valves closing or opening .When the water temperature below 8?. This causes the sensor to move and open a tiny passage so that water can drain out, this prevents water from freezing inside the pipe. When the temperature below 4 ?,the valve opened completely. The water will be flow out from the solar panel . When the temperature above 8?, the valve will be closed.